Active and reactive power control via currents of a rotor’s d and q components with nonlinear predictive control strategy in a doubly fed induction generator based on wind power system | ||
Energy Equipment and Systems | ||
مقاله 7، دوره 3، شماره 2، آذر 2015، صفحه 143-157 اصل مقاله (1.66 M) | ||
نوع مقاله: Research Paper | ||
شناسه دیجیتال (DOI): 10.22059/ees.2015.56038 | ||
نویسندگان | ||
Hamed Javaheri Fard؛ Hamid Reza Najafi؛ Hossein Eliasi | ||
Faculty of Electrical and Computer Engineering, University of Birjand, Iran | ||
چکیده | ||
Wind energy today, has attracted widespread interest from among a variety of sources of renewable energy in the world. Owing to the increasing demand for production of electrical energy for electricity networks by using wind power, it is essential that wind power plants are actively incorporated in the network’s performance using an appropriate control system. In general, these wind power plants consist of various types of wind turbines and generators, one of them being a doubly fed induction generator (DFIG). Strict and total control of DFIG is necessary for maintaining a high level of efficiency in utilizing the advantages and benefits of a modern wind plant. To achieve this aim, using the linear controllers is a difficult method because the wind plants involve some uncertainties. Nevertheless, there exists an unstable condition which may reduce the DFIG system’s performance. In this research, a predictive control has been proposed for power control in order to overcome these problems. Control is established by optimizing a Cost Function considering the reality of the tracking factors. The prediction has been done on the basis of a DFIG model. Finally, results of the simulations carried out proved the performance of the controller. | ||
کلیدواژهها | ||
Active and Reactive Power Control؛ Doubly Fed Induction Generator؛ Model-Based Predictive Control؛ Wind Energy | ||
مراجع | ||
[1]Tourou P., Sourkounis C.: Review of Control Strategies for DFIG-Based Wind Turbines under Unsymmetrical Grid Faults, Ecological Vehicles and Renewable Energies (EVER), IEEE Conference Publications, (2014) 1-9. [2]Boula am K., Boukhelifa A.: A Fuzzy Sliding Mode Control for DFIG-Based Wind Turbine Power Maximisation, Power Electronics, Machines and Drives (PEMD), IET Conference Publications, (2014) 1-6. [3]Mohammadi.J., Vaez-Zadeh S., Afsharnia S., Daryabeigi E.: A Combined Vector and Direct Power Control for DFIG-Based Wind Turbines, Sustainable Energy, IEEE Trans on, (2014) 767-775. [4]Esmaeeli M.R., Kianinejad R., Razzaz M.: Field Oriented Control of DFIG Based on Modified MRAS Observer, Electrical Power Distribution Networks (EPDC), Proceedings of 17 th Conference on, (2012)1-7. [5]Ozsoy E.E., Golubovic E., Sabanovic A. ,Gokasan M.,: A Stator Voltage Oriented Doubly Fed Induction Generator Control Method with a Disturbance Observer, EUROCON, IEEE, (2013)1102-1107. [6]Shuhui Li., Challoo R., Nemmers M.J.,: Comparative Study of DFIG Power Control Using Stator-Voltage and Stator-Flux Oriented Frames, Power & Energy Society General Meeting, PES '09. IEEE, (2009)1- 8. [7]Naguru N.R., Karthikeyan A., Nagamani C., Kumar V.S.,: Comparative Study of Power Control of DFIG Using PI Control and FeedBack Linearization Control, Advances in Power Conversion and Energy Technologies (APCET), International Conference on, (2012)1-6. [8] De Oliveira R. G., Da Silva J. L., Silva S. R., Development of a New Reactive power control strategy in doubly-fed induction generators for wind turbines, Eletrônica de Potência, (2008) Vol. 13, No. 4, 277-284. [9] Poitiers F., Bouaouiche T., Machmoum M., Advanced Control of a Doubly-Fed Induction Generator for Wind Energy Conversion, Electric Power Syst. Res., (2009) Vol. 79, 1085-1096. [10] Guolian H., Zhentao W., Pan J., Jianhua Z., Multivariable Predictive Functional Control Applied to Doubly Fed Induction Generator Under Unbalanced Grid Voltage Conditions, Industrial Electronics and Applications, ICIEA, 4th IEEE Conference on, (2009) 2644-2650. [11] Guo J., Cai X., Gong Y., Decoupled Control of Active and Reactive Power for a Grid-Connected Doubly-Fed Induction Generator, in Proc. Third International Conference Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), (2008) 2620-2625. [12] Cheikh R., Belmili H., Drid S., Menacer A., Tiar M., Fuzzy Logic Control Algorithm of Grid Connected Doubly Fed Induction Generator Driven by Vertical Axis Wind Turbine in Variable Speed, Systems and Control (ICSC), 3rd International Conference on, (2013) 439-444. [13] Depenbrock M., Direct Self-Control (DSC) of Inverter-Fed Induction (1988) Vol. 3, No. 4, 420-429. [14] Mohammadi J., Vaez-Zadeh S., Afsharnia S., Daryabeigi E., A Combined Vector and Direct Power Control for DFIG-Based Wind Turbines, Sustainable Energy, IEEE Trans on, (2014) 767-775. [15] Datta R., Ranganathan V. T., Direct Power Control of Grid-Connected Wound Rotor Induction Machine without Rotor Position Sensors, IEEE Trans. Power Electron, (2001) Vol. 16, No. 3, 390-399. [16] Xu L., Cartwright P., Direct Active and Reactive Power Control of DFIG for Wind Energy Generation, IEEE Trans. Energy Convers, (2006) Vol. 21, No.3, 750-758. [17] Zhi D., Xu L., Direct power control of DFIG with constant switching frequency and improved transient performance, IEEE Trans. Energy Convers, (2007)Vol. 22, No.1, 110-118. [18] Alegria I. de, Andreu J., Ibanez P., Villate J. L., Gabiola I., Novel Power Error Vector Control for Wind Turbine with Doubly Fed Induction Generator, in Proc. 30th Annu. Conference IEEE Industrial Electronics Society, (IECON), (2004) Vol. 2, 1218-1223. [19] Xiao-Ming G., Dan S., Ben-Teng H., Ling-Ling H., Direct Power Control for Wind-Wurbine Driven Doubly-Fed Induction Generator with Constant Switch Frequency, in Proc. International Conference Electrical Machines and Systems, (2007) 253-258. [20] Fuentes E., Kalise D., Rodriguez J., Kennel R.M., Cascade-Free Predictive Speed Control for Electrical Drives, IEEE Trans. Industrial Electronics, (2014) 2176-2184. [21] Rameshkumar K., Sakthivel A., Vijayakumar P., Senthilkumar A., Performance Analysis of Model Predictive Control for Voltage Source Inverter, Green Computing Communication and Electrical Engineering (ICGCCEE), International Conference on, (2014) 1-5,. [22] Yongsoo C., Woo J.C., Kyo-Beum L., Model Predictive Control using a Three-Level Inverter for Induction Motors with Torque Ripple Reduction, Industrial Technology (ICIT), IEEE International Conference on, (2014)187-192. [23] Yongchang Z., Haitao Y., Model Predictive Torque Control of Induction Motor Drives With Optimal Duty Cycle Control, Power Electronics, IEEE Trans on, (2014) 6593-6603. [24] Xin-fang Z., Da-ping X., Yi-bing L., Predictive Functional Control of a Doubly Fed Induction Generator for Variable Speed Wind Turbines, in Proc. IEEE World Congress on Intelligent Control and Automation, (2004) Vol. 4, 3315-3319. [25] Abad G., Ángel R.M., Poza J., Three-Level npc Converter-Based Predictive Direct Power Control of the Doubly Fed Induction Machine at Low Constant Switching Frequency, IEEE Trans. Ind. Electron, (2008)Vol. 55, No. 12, 4417-4429. [26] Xiangjie L., Xiaobing K.,: Nonlinear Model Predictive Control for DFIG-Based Wind Power Generation, Automation Science and Engineering, IEEE Trans on, (2013)1-10. [27] Camacho E.F., Bordons A.C., Model Predictive Control, Springer, (2004). [28] Aggarwal A., Saini L.M., Singh B., Control Strategies for DFIG Based Grid Connected Wind Energy Conversion System, International Journal of Grid Distribution Computing, (2014) Vol.7, No.3, 49-60. [29] Liuping W., Model Predictive Control System Design and Implementation Using MATLAB, Springer, (2009). [30] Xu L., Cartwright P., Direct Active and Reactive Power Control of DFIG for Wind Energy Generation, IEEE Trans Energy Convers, (2006) Vol. 21, No. 3, 750-758. [31] Eliasi H., Menhaj M.B., Davilu H., Robust Nonlinear Model Predictive Control for a PWR Nuclear Power Plant, Progress in Nuclear Energy, Elsevier, (2012) Vol.54, No.1, 177-185. [32] Eliasi H., Menhaj M.B., Davilu H., Robust Nonlinear Model Predictive Control for Nuclear Power Plants in Load Following Operations with Bounded Xenon Oscillations, Nuclear Engineering and Design, Elsevier, (2011)Vol.241, No.2, 533-543. [33] Eliasi H., Davilu H., Menhaj M.B., Adaptive Fuzzy Model Based Predictive Control of Nuclear Steam Generators, Nuclear Engineering and Design, Elsevier, (2007) Vol.237, No.6, 668-676. [34] Javaheri Fard H., Najafi H.R., Predictive Algorithm in a Wind Turbine with Doubly Fed Induction Generator (DFIG) to Power Control Using the Rotor Current, 29 th International Power System Conference, Energy Research, (2014) 27-29 October; Tehran. Iran. [35] Javaheri Fard H., Najafi H.R., Eliasi H., Direct Predictive Control Strategy of Active and Reactive Powers, Applied to the Converter AC / DC / AC, in a Double-Fed Induction Generator Based Wind Turbine, 12th Technologies of Power Electronic Seminar, Sharif seminar on power electronics, Sharif University of Technology, (2015) 3-4 March; Tehran. Iran. Javaheri Fard H., Eliasi H., Najafi H.R., Direct Predictive Control Strategy of Active and Reactive Powers, Applied to the Converter AC / DC / AC, in a Double- Fed Induction Generator Based Wind Turbine, 7th Electric Power Generation Conference & Exhibition (EPGC). (2015)17-18 Feb; Bandarabas. Iran. [37] Javaheri Fard H., Najafi H.R., Najafi J., Offering a Variety of Configurations and Model Based Predictive Controller on Photovoltaic Inverter Systems, 4 th Annual Clean Energy Conference (ACEC 2014), Kerman University, (2014)25-26 June; Kerman, Iran. | ||