EFFECTS OF TEMPERATURE AND PERCENTAGE OF ORGANIC MODIFIER ON RETENTION AND SELECTIVITY IN RP-HPLC USING SOLVATION PARAMETER MODEL | ||
| Journal of Sciences, Islamic Republic of Iran | ||
| مقاله 6، دوره 14، شماره 4، اسفند 2003، صفحه 337-340 اصل مقاله (263.04 K) | ||
| نوع مقاله: Original Paper | ||
| نویسنده | ||
| M.R. Hadjmohammadi* | ||
| Reversed-phase liquid chromatography; Solvation parameter model | ||
| چکیده | ||
| Effects of temperature and percentage of organic modifier were studied on retention and selectivity in RP-HPLC using solvation parameter model. The system constants were determined by multiple linear regression analysis from experimental values in the retention factor for a group of different solutes with known descriptors by computer using the program SPSS/PC. The experimental results showed that the variation of percentages of organic modifier (5-20% V/V CH3CN) changes cavity formation (m = +3.55 to +2.53), dipole-dipole interactions (s = +0.62 to −0.64) and hydrogen-bond acidity (b = −2.41 to −3.27) terms. The variation of temperature (5-45°C) also changes cavity formation (m = +3.21 to +2.56) and dipole-dipole interactions (s = +0.34 to −0.22) terms. | ||
| کلیدواژهها | ||
| Reversed-phase liquid chromatography؛ Solvation parameter model | ||
|