تعداد نشریات | 161 |
تعداد شمارهها | 6,532 |
تعداد مقالات | 70,500 |
تعداد مشاهده مقاله | 124,088,639 |
تعداد دریافت فایل اصل مقاله | 97,191,600 |
Assessing Indoor Air Pollution within Different Areas of Female Beauty Centers and Exploring Their Relation to Various Respiratory Symptoms | ||
Pollution | ||
مقاله 9، دوره 2، شماره 3، مهر 2016، صفحه 357-364 اصل مقاله (359 K) | ||
نوع مقاله: Original Research Paper | ||
شناسه دیجیتال (DOI): 10.7508/pj.2016.03.009 | ||
نویسنده | ||
Saja Almarshad* | ||
BsRC, MSc ACP in Critical Care, Lecturer, Dammam University, College of Applied Medical Science, Respiratory Care Department, PO BOX 31441, Dammam, 2435, Saudi Arabia | ||
چکیده | ||
The staff working at beauty centers are exposed to various chemical products used daily in their working environment. Both hair dressers and nail technicians are exposed to chemicals that are known to have an influence on the respiratory system. In order to evaluate such influence, this cross-sectional observational study was conducted on a randomly selected 14 beauty centers in Dammam City, Saudi Arabia. At the investigated salons, both of respiratory symptoms and the quality of air were evaluated and data were analyzed statistically. 40.5% out of the 79 subjects included in the study were hairdressers, 17.7% were nail technicians and (41.8%) were working in both of the previously mentioned areas as part of their everyday practice. The staff complained of respiratory symptoms which include dyspnea, cough, phlegm, wheeze, and shortness of breath. Both hairdressers and nail technicians developed respiratory symptoms while working in the salons. Indoor Air pollution was assessed and many data were out of the normal standard ranges which include: relative humidity (RH), volatile organic compounds (VOC), carbon dioxide (CO2), and ammonia (NH3). We conclude that good ventilation is required to reduce the influence of such substances on the respiratory symptoms of the staff working at salons. | ||
کلیدواژهها | ||
Air Quality؛ beauty centers؛ hairdressers؛ nail technicians؛ particulate matters؛ respiratory symptoms | ||
مراجع | ||
Brisman, J., Albin, M., Rylander, L., Mikoczy, Z., Lillienberg, L., Höglund, A.D., Torén, K., Meding, B., Diab, K.K., Nielsen, J. (2003). The incidence of respiratory symptoms in female Swedish hairdressers, Am. J. Ind. Med., 44 (6), 673–678. Cotes, J.E. and Chinn D.J. (2007). MRC questionnaire (MRCQ) on respiratory, Occupational Medicine, 57 (5), 388-388. Diab, K.K., Jönsson, B.A.G., Axmon, A. and Nielsen, J. (2014). Work-related airway symptoms, nasal reactivity and health-related quality of life in female hairdressers: a follow-up study during exposure. Int Arch Occup Environ. Health, 87(1), 61-71. Goldin, L.J., Ansher, L., Berlin, A., Cheng, J., Kanopkin, D., Khazan, A., Kisivuli, M., Lortie, M., Bunker Peterson, E., Pohl, L., Porter, S., Zeng, V., Skogstrom, T., Fragala, M.A., Myatt, Stewart T.A. and Allen, J.G. (2014). Indoor Air Quality Survey of Nail Salons in Boston, J Immigr Minor Health, 16 (3), 508-514. Hashemi, N., Boskabady, M.H., Nazari, A. (2010). Occupational exposures and obstructive lung disease: a case-control study in hairdressers', Respir Care, 55 (7), 895–900. Hollund, B.E., Moen, B.E., Lygre, S.H., Florvaag, E., Omenaas, E. (2001). Prevalence of airway symptoms among hairdressers in Bergen, Norway, Occup Environ Med, 58 (12), 780–785. Hollund, B.E., Moen, B.E. (1998). Chemical exposure in hairdresser salons: effect of local exhaust ventilation, Ann Occup Hyg, 42 (4), 277–282. Leino, T. (1999). Working Conditions and Health in Hairdressing Salons, Appl Occup Environ Hyg, 14 (1), 26-33. Lysdal, S.H., Mosbech H., Johansen J.D., Søsted H. (2014). Asthma and respiratory symptoms among hairdressers in Denmark: Results from a register based questionnaire study, Am J Ind Med, 57 (12), 1368-1376. Maneli, M.H., Smith, P. and Khumalo, N.P. (2014). Elevated formaldehyde concentration in Brazilian keratin type hair-straightening products: A cross-sectional study. J Am Acad Dermatol, 70 (2), 276-280. Markowicz, P. and Larsson, L. (2015). Influence of relative humidity on VOC concentrations in indoor air. Environ Sci Pollut Res Int., 22 (8), 5772. Messer, L.C., Jagai, J.S., Rappazzo, K.M. and Lobdell, D.T. (2014). Construction of an environmental quality index for public health research. Environ Health, 13(1), 39. Moscato, G., Pignatti, P., Yacoub, M.R., Romano, C., Spezia, S., Perfetti, L. (2005). Occupational asthma and occupational rhinitis in hairdressers, Chest, 128 (5), p3590–3598. NCBI (1986). Indirect health effects of relative humidity in indoor environments. [Online] Available at: <http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1474709/> [Accessed 29 May 2015]. Nemer, M., Sikkeland, L.I.B., Kasem, M., Kristensen, P., Nijem, K., Bjertness, E., Skare, Ø., Bakke, B., Kongerud, J. and Skogstad, M. (2015).Airway inflammation and ammonia exposure among female Palestinian hairdressers: a cross-sectional study, Occup Environ Med., 72 (6), 428. Roelofs C., Do T. (2012). Exposure Assessment in Nail Salons: An Indoor Air Approach, Inter Scholarly Research Notices, 2012 (4), 1-7 Roelofs C., Azaroff L.S., Holcroft C., Nguyen H., Doan T. (2008). Results from a community-based occupational health survey of Vietnamese-American nail salon workers, J Immigr Minor Health, 10 (4), 353-361. Sexton, K., Adgate, J.L., Ramachandran, G., Pratt, G.C., Mongin, S.J., Stock, T.H. and Morandi, M.T. (2004). Comparison of Personal, Indoor, and Outdoor Exposures to Hazardous Air Pollutants in Three Urban Communities, Environ Sci Technol., 38 (2), 423-430. Shoshkes, M., Banfield, W.G., Jr., Rosenbaum, S.J. (1950). Distribution, Effect and Fate of Oil Aerosol Particles retained in the Lungs of Mice, Arch. Indust. Hyg & Occupational Med, 1 (1), 20–35. Skoufi, G.I., Nena, E., Kostikas, K., Lialios, G.A., Constantinidis, T.C., Daniil, Z. and Gourgoulianis, K. (2013). Work-Related Respiratory Symptoms and Airway Disease in Hairdressers. Int J Occup Environ Med, 4 (2), 53-60. Tsigonia, A., Lagoudi, A., Chandrinou, S., Linos, A., Evlogias, N. and Alexopoulos, E.C. (2010). Indoor Air in Beauty Salons and Occupational Health Exposure of Cosmetologists to Chemical Substances Int J Environ Res Public Health. 7 (1), 314–324. Turanjanin, V., Vučićević, B., Jovanović, M., Mirkov, N. and Lazović, I. (2014). Indoor CO2 measurements in Serbian schools and ventilation rate calculation. Energy, 77 (c), 290-296. US EPA, (2014). Carbon Monoxide. [Online] Available at: <http://www.epa.gov/oar/carbonmonoxide/health.html> [Accessed 13 April 2015]. US EPA, (2012). An Introduction to Indoor Air Quality: Volatile Organic Compounds (VOCs). [Online] Available at: <http://www.epa.gov/iaq/voc.html> [Accessed 13 April 2015] Zhao, Y., Huang, D., Huang, L. and Chen, Z. (2014). Hydrogen Peroxide Enhances the Oxidation of Oxygenated Volatile Organic Compounds on Mineral Dust Particles: A Case Study of Methacrolein. Environ Sci Technol, 48(18), 10614-10623. | ||
آمار تعداد مشاهده مقاله: 2,196 تعداد دریافت فایل اصل مقاله: 2,711 |