Numerical study of the effect of the tip gap size and using a single circumferential groove on the performance of a multistage compressor | ||
Journal of Computational Applied Mechanics | ||
مقاله 5، دوره 50، شماره 1، شهریور 2019، صفحه 54-62 اصل مقاله (1.11 M) | ||
نوع مقاله: Research Paper | ||
شناسه دیجیتال (DOI): 10.22059/jcamech.2018.257242.278 | ||
نویسندگان | ||
Morteza Hamzezade؛ Mohsen Agha Seyed Mirzabozorg* ؛ Mehrdad Bazazzadeh | ||
Faculty of Mechanical Engineering, Malek Ashtar University of Technology, Isfahan, Iran | ||
چکیده | ||
The effect of the tip gap size on the performance of a multistage axial compressor was studied by means of computational fluid dynamics (CFD). It was found that the performance of the compressor was very sensitive to the size of the tip gap. By increasing the gap size, the stall margin value, the total pressure ratio and the compressor efficiency reduced considerably. The flow field at the tip region of the blades at the near-stall point showed that the size of the blockage grew with an increase in the gap size. Afterward, the effect of various single circumferential grooves- having specified widths and depths at different placement positions- on the performance were investigated in the reference gap. The stall margin increased about 7% with negligible reduction of the peak efficiency using one of the grooves which placed next to the trailing edge of the first-stage rotor. Also, this groove increased the stall margin in other tip gap sizes. Investigation of the flow field of the tip region in the reference gap showed that when the groove was used, there was a reduction in the back-flow near the trailing edge of the first-stage rotor. Consequently, the stall occurred at a lower mass flow rate. | ||
کلیدواژهها | ||
Circumferential groove؛ Multistage compressor؛ Tip gap؛ Stall margin؛ CFD | ||
مراجع | ||
[1] R. D. Moore, G. Kovich, R. J. Blade, Effect of casing treatment on overall and blade element performance of a compressor rotor, 1971.
[2] D. Prince, D. Wisler, D. Hilvers, A study of casing treatment stall margin improvement phenomena, in Proceeding of, American Society of Mechanical Engineers, pp. V01AT01A059-V01AT01A059.
[3] L. M. Wenzel, J. E. Moss, C. M. Mehalic, 1975, Effect of casing treatment on performance of a multistage compressor, National Aeronautics and Space Administration,
[4] A. Azimian, R. Elder, A. McKenzie, Application of recess vaned casing treatment to axial flow fans, Journal of Turbomachinery, Vol. 112, No. 1, pp. 145-150, 1990.
[5] A. Crook, E. M. Greitzer, C. Tan, J. Adamczyk, Numerical simulation of compressor endwall and casing treatment flow phenomena, Journal of turbomachinery, Vol. 115, No. 3, pp. 501-512, 1993.
[6] H. Fujita, H. TAKATA, A study on configurations of casing treatment for axial flow compressors, Bulletin of JSME, Vol. 27, No. 230, pp. 1675-1681, 1984.
[7] B. H. Beheshti, J. A. Teixeira, P. C. Ivey, K. Ghorbanian, B. Farhanieh, Parametric study of tip clearance–casing treatment on performance and stability of a transonic axial compressor, in Proceeding of, American Society of Mechanical Engineers, pp. 395-404.
[8] C. Guinet, J. A. Streit, H.-P. Kau, V. Gümmer, Tip gap variation on a transonic rotor in the presence of tip blowing, in Proceeding of, American Society of Mechanical Engineers, pp. V02AT37A002-V02AT37A002.
[9] S. Puterbaugh, M. Brendel, Tip clearance flow-shock interaction in a transonic compressor rotor, Journal of propulsion and power, Vol. 13, No. 1, pp. 24-30, 1997.
[10] M. Furukawa, M. Inoue, K. Saiki, K. Yamada, The role of tip leakage vortex breakdown in compressor rotor aerodynamics, in Proceeding of, American Society of Mechanical Engineers, pp. V001T01A054-V001T01A054.
[11] M. Furukawa, K. Saiki, K. Yamada, M. Inoue, Unsteady flow behavior due to breakdown of tip leakage vortex in an axial compressor rotor at near-stall condition, in Proceeding of, American Society of Mechanical Engineers, pp. V001T03A112-V001T03A112.
[12] I. Wilke, H.-P. Kau, A numerical investigation of the influence of casing treatments on the tip leakage flow in a HPC front stage, in Proceeding of, American Society of Mechanical Engineers, pp. 1155-1165.
[13] Y. Ito, T. Watanabe, T. Himeno, Effects of endwall contouring on flow instability of transonic compressor, Int. J. Gas Turb. Propul. Power Sys, Vol. 2, No. 1, pp. 24-29, 2008.
[14] H. D. Vo, C. S. Tan, E. M. Greitzer, Criteria for spike initiated rotating stall, Journal of turbomachinery, Vol. 130, No. 1, pp. 011023, 2008.
[15] J.-P. Chen, M. D. Hathaway, G. P. Herrick, Prestall behavior of a transonic axial compressor stage via time-accurate numerical simulation, Journal of Turbomachinery, Vol. 130, No. 4, pp. 041014, 2008.
[16] G. Legras, N. Gourdain, I. Trebinjac, Numerical analysis of the tip leakage flow field in a transonic axial compressor with circumferential casing treatment, Journal of Thermal Science, Vol. 19, No. 3, pp. 198-205, 2010.
[17] T. Kroeckel, S. Hiller, P. Jeschke, Application of a multistage casing treatment in a high speed axial compressor test rig, in Proceeding of, American Society of Mechanical Engineers, pp. 309-318.
[18] D.-W. Kim, J.-H. Kim, K.-Y. Kim, Aerodynamic performance of an axial compressor with a casing groove combined with injection, Transactions of the Canadian Society for Mechanical Engineering, Vol. 37, No. 3, pp. 283-292, 2013.
[19] R. Taghavi-Zenouz, S. Eslami, Effects of casing treatment on behavior of tip leakage flow in an isolated axial compressor rotor blade row, Journal of the Chinese Institute of Engineers, Vol. 36, No. 7, pp. 819-830, 2013.
[20] J.-H. Kim, K.-J. Choi, K.-Y. Kim, Aerodynamic analysis and optimization of a transonic axial compressor with casing grooves to improve operating stability, Aerospace Science and Technology, Vol. 29, No. 1, pp. 81-91, 2013.
[21] J. Kim, K. Choi, K. Kim, Performance evaluation of a transonic axial compressor with circumferential casing grooves, Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, Vol. 226, No. 2, pp. 218-230, 2012.
[22] J. H. Kim, K. Y. Kim, K. H. Cha, Effects of number of circumferential casing grooves on stall flow characteristics of a transonic axial compressor, in Proceeding of, Trans Tech Publ, pp. 727-732.
[23] Y. Sakuma, T. Watanabe, T. Himeno, D. Kato, T. Murooka, Y. Shuto, Numerical analysis of flow in a transonic compressor with a single circumferential casing groove: influence of groove location and depth on flow instability, Journal of Turbomachinery, Vol. 136, No. 3, pp. 031017, 2014.
[24] X. Zhou, Q. Zhao, X. Xiang, W. Cui, Investigation of groove casing treatment in a transonic compressor at different speeds with control volume method, Proceedings of the Institution of Mechanical Engineers, Part G: Journal of Aerospace Engineering, Vol. 230, No. 13, pp. 2392-2408, 2016.
[25] M. A. S. Mirzabozorg, M. Bazazzadeh, M. Hamzezade, Numerical study on the effect of single shallow circumferential groove casing treatment on the flow field and the stability of a transonic compressor, Journal of Applied Fluid Mechanics, Vol. 10, No. 1, pp. 257-265, 2017.
[26] F. Menter, J. C. Ferreira, T. Esch, B. Konno, A. Germany, The SST turbulence model with improved wall treatment for heat transfer predictions in gas turbines, in Proceeding of, 2-7.
[27] F. R. Menter, Review of the shear-stress transport turbulence model experience from an industrial perspective, International Journal of Computational Fluid Dynamics, Vol. 23, No. 4, pp. 305-316, 2009.
[28] S. L. Dixon, C. Hall, 2010, Fluid mechanics and thermodynamics of turbomachinery, Butterworth-Heinemann,
[29] J. Dunham, CFD validation for propulsion system components (la validation CFD des organes des propulseurs), ADVISORY GROUP FOR AEROSPACE RESEARCH AND DEVELOPMENT NEUILLY-SUR-SEINE (FRANCE), pp. 1998. | ||
آمار تعداد مشاهده مقاله: 526 تعداد دریافت فایل اصل مقاله: 400 |